{"product_id":"141681","title":"Oxygen Detector, Controller and Transducer for Fire Detection Panel","description":"\u003ch2\u003e Oxygen Detector, Controller and Transducer for Fire Detection Panel\u003c\/h2\u003e\n\u003cp\u003e\u003c\/p\u003e \u003cp\u003eThe MACURCO OX-6 is a low-voltage detector, controller, and transducer, integrating dual relays, selectable 4-20 mA output, buzzer, and digital display. It is an electronic sensing system used to measure oxygen (O2) concentration and provide feedback and automatic ventilator\/exhaust control to maintain appropriate oxygen concentration in commercial applications. The OX-6 is a low-level meter capable of recording 0-20% oxygen level.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eCharacteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e Fan relay activation: selectable\u003c\/li\u003e\n\n\u003cli\u003e Outputs: Fan Relay, Alarm Relay and 4-20mA current loop\u003c\/li\u003e\n\n\u003cli\u003e Controls: Digital display (0-25% v\/v), buzzer, fan delay, minimum fan run time.\u003c\/li\u003e\n\n\u003cli\u003e Factory calibrated\u003c\/li\u003e\n\n\u003cli\u003e Mounts in a standard 4' x 4' electrical box\u003c\/li\u003e\n\n\u003cli\u003e 0.5 A NO or NC alarm relay connects to warning devices or control panels\u003c\/li\u003e\n\n \u003cli\u003eThe 5A SPDT fan relay controls valves, louvers or extractors\u003c\/li\u003e\n\n\u003cli\u003e 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel\u003c\/li\u003e\n\n\u003cli\u003e Supervised system design: The trouble detector will activate the fan relay and the alarm relay.\u003c\/li\u003e\n\n\u003cli\u003e ETL listed to UL 61010-1, CAN CSA C22.2 No 61010-1\u003c\/li\u003e\n\n\u003cli\u003e Fan relay: 5 A, 240 VAC\u003c\/li\u003e\n\n\u003cli\u003e Fan relay with delay of 0, 1, 3 (default), 5 and 10 minutes\u003c\/li\u003e\n\n\u003cli\u003e Setting minimum fan runtime in state 0 (default), 3, 5, 10 or 15 minutes\u003c\/li\u003e\n\n\u003cli\u003e Alarm relay: 0.5A 120V, 60VA\u003c\/li\u003e\n\n\u003cli\u003e Operating temperature: -18 to 52°C, 10 to 90% relative humidity non-condensing\u003c\/li\u003e\n\n\u003cli\u003e Power supply: 12 to 24 Vac or 12 to 32 Vdc\u003c\/li\u003e\n\n\u003cli\u003e Current: @ 24 Vdc 75 mA in alarm, 50 mA in fan relay and 23 mA in standby state.\u003c\/li\u003e\n\n\u003cli\u003e Dimensions: 114 x 102 x 54 mm \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SF208P\/196708-deteccion_de_gas_(1).jpg\" alt=\"\" width=\"800\" height=\"800\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"MACURCO - AERIONICS","offers":[{"title":"Default Title","offer_id":47321238667506,"sku":"OX-6","price":0.0,"currency_code":"COP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/0770\/6098\/files\/OX6-l.png?v=1740342336","url":"https:\/\/www.coltienda.co\/en\/products\/141681","provider":"Colombiatel Telecomunicaciones","version":"1.0","type":"link"}