SAFE FIRE DETECTION INC.
152 Meter Spool of Heat Detector Cable, Fixed Temperature 68 Degrees Celsius, Black Nylon Coating for Outdoor Applications, with Steel Guide
152 Meter Spool of Heat Detector Cable, Fixed Temperature 68 Degrees Celsius, Black Nylon Coating for Outdoor Applications, with Steel Guide
Couldn't load pickup availability
152 Meter Spool of Heat Detector Cable, Fixed Temperature 68 Degrees Celsius, Black Nylon Coating for Outdoor Applications, with Steel Guide
SAFE Linear Heat Detection (LHD)
It uses advanced polymers and a newly developed alloy to provide exceptional detection, durability, and design flexibility. At the core of SafeCable is a twisted pair of extremely low-resistance tri-metallic conductors, which are sheathed with new, advanced thermal polymers. These polymers are chemically engineered to decompose at specific, fixed temperatures, allowing the twisted conductors to make contact and initiate an alarm.


Trays with electrical cables
Trays with electrical cables
A cable tray is an assembly of sections forming a rigid structural system to support cables. These support cables in the same way that bridges support cars and transportation systems. In addition to straight cable tray sections, there are elbows, tees, crosses, and vertical sections, which require a fire detection system that follows the same route as the cables.
Fire detection
Linear Heat Detection (LHD) is a highly effective and low-cost solution for protecting cable trays. The flexible LHD cable can be installed inside the tray, with the cables following the exact same route while remaining in close proximity to the cables for rapid detection.
Electrical Room
Electrical cables laid in cable trays may be high-voltage and can break over time and with use. Over time, the cables can overheat, causing fires. Cables in trays that are not properly arranged are more susceptible to fire due to increased access to oxygen on the cable surface.
Characteristics
- Alarm temperature fixed at 68 °C
- Compatible with any Fire Detection panel
- Up to 4,572 meters of linear coverage per zone
- Excellent durability for outdoor environments
- Multiple alarm temperatures in one zone
- It is not necessary to replace the entire cable after an alarm.
- Approved for up to 10.7 meters of spacing
- The lowest drag of any LHD
- Guide wire, for easy installation
- Resistance: 0.164 homs/m
- Maximum rated voltage: 30VAC, 42VDC
Important note: Price per 152 meter coil